Lavspenning/Kabler/Signalkabel - LXX-1,4 FEBI-44D

1 SCOPE

1.1 Purpose

The purpose of the technical specification is to provide guidance for the production, test procedures and delivery of products according to stated requirements. The technical specification contains technical and functional requirements to be fulfilled.

The cables shall provide capability to transfer power and/or data signals to external safety facilities. The cables shall be free of halogens and self-extinguishing. The cables shall withstand relevant loads that may be present in normal operation of safety facilities for railways.

F (1. letter) = massive insulation of PE / PP with filling compound (Vaseline)
E (2. letter) = sheath of PE / PP
B (3. letter) = armouring (2 steel tapes)
I (4. letter) = outer sheath of halogen-free polymer (self-extinguishing)

The cables will be a part of the safety facilities of the railway infrastructure.

1.2 History

The cables consist of two or more twisted pairs organized in quads. Previous version was in Norwegian. The cables in this specification have got the designation starting with FEBI – and all variants should include Vaseline and steel tapes for protection and EMC.

2 REQUIREMENTS

2.1 Electrical requirements

a) The cables contain quad cable elements.

b) Electrical properties at 20 °C:

1 Pair capacitance, nominal: 44 nF/km
2 Pair capacitance, maximum single value: 49 nF/km
3 DC loop resistance, maximum: 25,0 ohm/km
4 Insulation resistance: 1 Gohm x km
5 Voltage test, conductor to conductor: 4 kV DC
6 Voltage test, conductor to armouring / shield: 2,5 kV DC
7 Nominal Voltage 600 V

2.2 Cable types and mechanical requirements

a) The following mechanical requirements apply:

Number of pairs Designation F.number Min. bending diameter
(mm)
Max. longitudinal load
(N)
Weight (approx.)
(kg/km)
2 L2-1,4 FEBI-44D To be stated 300 150 300
6 L6-1,4 FEBI-44D To be stated 500 450 690
10 L10-1,4 FEBI-44D To be stated 500 750 850
14 L14-1,4 FEBI-44D To be stated 600 1050 1250

A conductor diameter of 1,4 mm is equivalent to 1,5 mm².

F.number is a unique 9-digit number identifying the specific production variant.

2.3 Constructions of cable elements and cables

a) The following dimensions apply:

Number of conductors 2 6 10 14
Conductor diameter, solid annealed Cu (mm) 1,4 1,4 1,4 1,4
Outer insulation diameter, solid PE (mm) 3,2 3,2 3,2 3,2
Quad diameter (mm) 7,7 7,7 7,7 7,7
Identification tape (numbered) --- number:
1 - 2- 3
number:
1 - 2 ... 5
number:
1 - 2 ... 7
Cable core (mm)
(filled with Vaseline)
(7,7) 15,7 16,8 22,8
Inner sheath, black PE (mm) 10,2 18,4 19,5 25,7
Galvanic steel tapes (mm) (2*0,2)
11,6
(2*0,2)
19,8
(2*0,2)
21,0
(2*0,2)
27,1
Outer sheath, black LSFROH (mm)
(Low Smoke Flame Retardant Zero Halogen)
14,8 23,2 24,4 30,5
Number of quads within layer(s): 1 3 5 1
+6

b) The conductors shall have a colour coding permeating the insulation:

Conductor Insulation colour
1 Red
2 Black
3 White
4 Blue

c) The Vaseline shall have a melting point above 80 °C. (A thin non-conductive tape may be applied over the core filled with Vaseline.)

d) A rip thread shall be included under the inner sheath to assist easy removal of the inner sheath.

e) Just inside the steel tapes a multi-thread tinned copper conductor of minimum 1,5 mm² shall be included.

f) The two steel tapes shall be revolved with an overlap.

g) A rip thread may be included under the outer sheath to assist easy removal of the outer sheath.

h) The compound of the outer sheath shall be selected to minimize problems with rodents and UV radiation.

2.4 Tools

a) It shall be possible to terminate the cables without the use of special tools.

2.5 Fire properties

a) The cables shall fulfil the requirements in IEC 60332-1 (related to fire).

2.6 Markings

a) The outer sheath of the cable shall have easy readable and durable markings with the following information:

  1. manufacturer's name
  2. designation
  3. F.number
  4. accumulative length at every meter of the actual production length (note)
  5. preferably also a unique production identity
  6. year of production

(Note) The first and the last length figures shall be readable at/on the production package (drum or other package).

b) € marking is not relevant.

2.7 Quality certificate

a) A quality certificate containing test results or control check points shall accompany the cable and the invoice. The quality certificate shall indicate the purchase number.

2.8 Documentation, language

a) Product sheets shall be available in Norwegian.

3 ENVIRONMENTAL CONCERNS

a) All cables shall be fitted with protective caps at both ends to avoid intrusion of moisture and contamination.

b) Production, use and disposal of the products shall be possible obeying national regulations (Forurensningsloven).

4 REFERENCES

Undated references are supposed to be the last updated version, including any amendments and updates.

  1. IEC 60304: Standard colours for insulation for low-frequency cables and wires.
  2. IEC 60708: Low frequency cables with polyolefin Part 1. General design details and requirements, relevant clauses.
  3. IEC 60332-1: Test on electric cables under fire conditions Part 1: Test on a single vertical insulated wire or cable


5 CONFORMANCE LIST

Clause req. Complient:
(YES / NO )
... any comments
2. ---/--- REQUIREMENTS
2.1 ---/--- Electrical requirements
a
2.2 ---/--- Cable types and mechanical requirements
a
2.3 ---/--- Constructions of cable elements and cables
a
b
c
d
e
f
g
h
2.4 ---/--- Tools
a
2.5 ---/--- Fire properties
a
2.6 ---/--- Markings
a
b
2.7 ---/--- Quality certificate
a
2.8 ---/--- Documentation, language
a
3. ---/--- ENVIRONMENTAL CONCERNS
a
b